Configure a Digi-Star GT 460 Grain Cart Scale for Broadcast

Configure a Digi-Star 460 grain cart scale to properly  Broadcast information and for Bluetooth compatability in the Conservis Row Crop App.

What’s Needed:  

  • A Digi-Star GT 460 grain cart scale installed, tested and working
  • A compatible Android or iOS device
  • Conservis Bluetooth adapter set for 8/N/1 communication
  • A pen or pencil

Procedure:

**NOTE:** Please write original values on the blank line to the right of the steps.

  1. Connect the Conservis Bluetooth adapter to the bottom of the scale-indicator (Serial COM1-2).
  2. Power on the scale.
  3. Enter 213 and press to enter the settings for SCOREM. __________________
    1. Use the up arrow to scroll through the selections until you reach 21. This setting will put the scale into Broadcast mode. Press to save the setting.
  4. Enter 215 and press to enter the settings for COM IN. __________________
    1. Use the up arrow to scroll through the selections until you reach EZ2CMD. Press to save the setting. Confirm EZ2CMD is selected, not EZCMD – an easy mistake.
  5. Enter 217 and press to enter the settings for MEDIA. __________________
    1. Use the up arrow to scroll through the selections until you reach DDL. Press to save the setting.
  6. Enter 271 and press to enter the settings for COM 1-1 PARITY. _____________
    1. Use the up arrow to scroll through the selections until you reach 8N1. Press to save the setting.
  7. Enter 275 and press to enter the settings for COM 1-1 BAUD RATE. __________________
    1. Use the up arrow to scroll through the selections until you reach 9600. Press to save the setting.
  8. Enter 272 and press to enter the settings for COM 1-2 PARITY. _____________
    1. Use the up arrow to scroll through the selections until you reach 8N1. Press to save the setting.
  9. Enter 276 and press to enter the settings for COM 1-2 BAUD RATE. __________________
    1. Use the up arrow to scroll through the selections until you reach 9600. Press to save the setting.
  10. Power off the scale, wait 5 seconds and then power it back on. The scale should now be prepared to have the Mobile Device paired to the Bluetooth adapter and the Harvest application configured.